Stricter Standards For Fire Escape Safety

Exclusive: Philadelphia Licenses And Inspections To Enact Stricter Standards For Fire Escape Safety Amid Controversy By Crystal CranmoreDecember 12, 2019 at 5:45 pmFiled Under:Local, Local TV, Philadelphia Licenses and Inspections, Philadelphia News PHILADELPHIA (CBS) — Questions by CBS3 have prompted Philadelphia Licenses and Inspections to enact stricter standards to ensure fire escapes are safe and capable of helping residents […]

Read more...

PA Firefighter Recovers from Rooftop Fall

Raw video captures Harrisburg crews battling a blaze that damaged five homes and injured a firefighter following a first-floor fall. SEAN SAURO NOVEMBER 18, 2019 THE PATRIOT-NEWS, HARRISBURG, PA. A firefighter who fell from a first-floor rooftop while battling a Saturday night blaze that damaged five houses in Harrisburg is now at home recovering from […]

Read more...

National Code

2012 IFC 1104.16.5.1 Fire escape stairs must be examined every 5 years ,by design professional or others acceptable and inspection report must be submitted to the fire code official.

IBC 1001.3.3 All fire escapes shall be examined and/or tested and certified every five years by a design professional or others acceptable who will then submit an affidavit city official.

NFPA LIFE SAFETY CODE 101  7.2.8.6.2 The Authority Having Jurisdiction (AHJ) shall approve any fire escape by Load Test or other evidence of strength (Certification).

OSHA 1910.37 Exit routes must be maintained during construction, repairs, alterations or provide alternative egress with equivalent level of safety. (permit issued if egress is certified or with egress scaffolding) 

Philadelphia Code

IMPORTANT:

The owner of any building with fire escapes or fire escape balconies shall be responsible for retaining a Professional to conduct periodic inspections of the fire escapes and fire escape balconies, and to prepare and file a report on such inspection with the owner. All fire escapes and fire escape balconies must be inspected and the reports submitted by July 1, 2017.

A summary of that inspection must be submitted to the Department of Licenses and Inspections on a form titled

“Summary Inspection Report of Fire Escapes and Fire Escape Balconies”.

The City of Philadelphia’s Property Maintenance Code requires all building owners to maintain their buildings in good repair, structurally sound and sanitary so as to not impose a threat to the public. Additionally, the Fire Code establishes specific requirements for periodic inspections of fire escapes and fire escape balconies and the filing of reports of such inspections. This document serves to inform the public of the method of reporting those inspections to the Department.

See Section F-1011.1 of the Philadelphia Fire Code BELOW for more details.

Philadelphia Fire Escape Inspection

Fire Escapes Philadelphia

Philadelphia residential building owners, including private homeowners, are also responsible for complying with statewide fire codes that regulate fire escapes. All Philadelphia residential buildings that have living space on the second floor or above require at least two means of escape for residents. This usually means a normal entrance stairway and an escape window. These windows must be less than 3 feet above the interior floor. If they are more than 6 feet above the exterior ground, they require ladders or exterior stairs made from fire-retardant wood or metal.

Maintenance and Egress

The Philadelphia fire code borrows from the International Residential Code and similar standards to provide requirements for residential fire escape maintenance. Building owners are responsible for inspecting and repairing fire escape stairs and escape windows, as well as alarms and sprinkler systems. Homeowners with living space in basements must install egress windows to provide secondary escape routes. Philadelphia and Pennsylvania state authorities can impose fines or require alterations to residential buildings that fail to meet applicable fire escape code requirements.

F-1011.1.2 Materials and strength.

Components of fire escapes shall be constructed of noncombustible materials. Fire escapes and balconies shall support the dead load plus a live load of not less than 100 pounds per square foot (4.78 kN/m2). Fire escapes and balconies shall be provided with a top and intermediate handrail on each side.

F-1011.1.10 Inspection procedures.

5. To be considered Safe or Safe With a Repair and Maintenance Program, the fire escape and fire escape balconies shall be capable of meeting or exceeding the load requirements of Section F-1011.1.2. This load requirement can be met by either an engineering analysis by the Professional or by conducting a load test. Any load test shall be witnessed by the Professional.


West PA Residents Questioning Fire Escape Safety

PHILADELPHIA (CBS) — Residents are questioning the safety of the building after two people were critically injured when a fire escape balcony collapsed at an apartment complex in West Philadelphia on Tuesday morning. It happened at Lexington Apartments on the 4200 block of Chester Avenue, shortly after 10 a.m. According to police, two men were […]

Read more...
balcony collapse

Two men critically injured in West Philly balcony collapse

Two men were critically injured Tuesday in the collapse of a third-floor fire escape landing in West Philadelphia, police said.

Read more...

By Carrie Bradon May 6, 2019

PITTSBURGH – An East Pittsburgh man is suing the owner and operator of his apartment over allegations it failed to maintain the fire escape.

Dominic C. Pennick filed a complaint on April 23 in the Allegheny County Court of Common Pleas against Donda Development Inc. alleging negligence.

According to the complaint, the plaintiff alleges on May 17, 2018, he was attempting to use the fire escape at the back of the apartment building to retrieve his neighbor’s garbage and he fell through the rusty escape and was injured.

The plaintiff alleges his fall was a result of the defendant’s failure to properly maintain the fire escape. 

The plaintiff is seeking all reasonable sums due and court costs. The plaintiff is represented by Wayne M. Chiurazzi of The Chiurazzi Law Group.

fire in apartment building – Germantown Philadelphia.

Tuesday, January 22, 2019 05:04PMPHILADELPHIA (WPVI) — Residents ran out into the frigid cold after a fire broke out in an apartment building in the Germantown section of Philadelphia. The trees surrounding the building now look like icicles, and cars parked on the street are covered in ice, after firefighters doused the building with water to […]

Read more...

Philly fire escape law not being followed

Expert says Philly fire escape law not being followed By Tom MacDonald April 25, 2017   This 2014 file photo shows a fourth-floor fire escape landing in Rittenhouse which collapsed with three people standing on it, killing one. (Emma Lee/WHYY, file) A deadline is rapidly approaching for inspecting every fire escape in Philadelphia. The requirement took […]

Read more...

Fire Escapes are “Ticking Time Bombs”

Many City Fire Escapes are “Ticking Time Bombs” By Kelly Bayliss Published Feb 26, 2014 at 3:55 PM | Updated at 3:02 AM EST on Feb 27, 2014 In the wake of last month’s fatal fire escape collapse that killed a 22-year-old man and injured two women, Philadelphia residents are concerned about the safety of […]

Read more...

Fire escape collapse leaves one injured in Brewerytown

BREWERYTOWN (WPVI) — A fire escape collapsed in Philadelphia’s Brewerytown section on Tuesday, sending one person to the hospital. The Action Cam was there as a man was wheeled into an ambulance on a stretcher just after 2 p.m. Though officials aren’t releasing much information, we know it happened in an alley near 29th Street […]

Read more...